Date: 9 July 2021
The basis for calculation has shifted from shear storage modulus to shear relaxation modulus. This shift makes the data more accurate, even if the calculated stresses and deflections are sometimes higher. The datasheets are available from the section of website.
Second, the datasets have received external validation.
We rely on our external partners to review and validate our datasets, which are based on direct measured values to EN 16613. The latest datasets are selectively verified on laminated glass using four-point bending to EN 1288, and a supporting paper is available upon .
Third, a wider temperature range is now available.
The temperature range for Saflex庐 Clear (R-series), Saflex庐 Structural and Saflex庐 DM has been extended down to 10掳C; therefore, any temperature between 10-60掳C range is now selectable. Stacks of R-series and Structural are still restricted to a lower limit of 20掳C and a maximum duration of one month.
One final note.
The units of the load types are now harmonized to (Pa, N/m and N) rather than before (kPa, kN/m and N).