黑料专区

FGIA Annual Conference Participants Tour Seismic Shake Table Test Site

Date: 28 February 2023
Source:
FGIA Annual Conference Participants Tour Seismic Shake Table Test Site
Photo source
FGIAonline.org

Date: 28 February 2023

More than 40 FGIA members had the opportunity to tour a one-of-a-kind seismic shake table test site as part of the FGIA 2023 Annual Conference.

The Natural Hazards Engineering Research Infrastructure (NHERI) TallWood Project shake table test will take place in the San Diego area, just miles away from where the conference was held in Coronado, CA. Those on the tour were able to see outside, inside and beneath the structure built on top of the shake table. At 10 stories tall, this is the largest test of its kind, and its construction is nearly complete.

鈥淢y team is leading an effort to test exterior facades as part of a test of a 10-story timber building,鈥 said Dr. Keri Ryan, University of Nevada, Reno, who is a co-investigator of the project, which began in 2016. The shake table facility completed a multi-year upgrade last spring, to extend the shaking capabilities from one direction to three axis translation and rotation. The construction of the building itself started in July. 鈥淲e designed and will test a 10-story building with mass timber products. The main focus is its seismic resilient timber rocking walls, built with massive timber panels.鈥

Two FGIA members donated windows to the project: and . Ryan said she and her research team anticipate the building can go through large earthquakes with very little damage. The exterior fa莽ade is made up of four sub-assemblies at the base of the building, all of which are attached to the main wood frame structure. The first three sub-assemblies feature cold-formed steel (CFS) framing with exterior aluminum composite (ACM) finish and windows, while the fourth is a curtain wall. All are detailed for drift compatibility, by providing horizontal and vertical joints. 鈥淣one of this has been tested in this way before,鈥 said Ryan.

  • 锘緾FS 1: This sub-assembly is platform framed with horizontal drift joints at the top of the wall. 鈥淪lip is intended to occur between those two tracks,鈥 said Ryan. 鈥淭he corner uses special joints that expand. We have the joint on two of the three stories.鈥 The third story without the joints serves as a reference, so the researchers can compare the performance with and without joints.
  • CFS 2: This sub-assembly is bypass framed with drift clips that allow the studs to slip relative to its diaphragm. 鈥淚n this one, we expect the floors to move, and the walls should basically stay straight,鈥 said Ryan. 鈥淎t the corner, we expect up to 10 inches of drift to be accommodated.鈥
  • CFS 3: Featuring spandrel units with ribbon windows, this sub-assembly also has slip joints at the top of the windows, between the window and the spandrels, while the spandrel framing is fixed to the diaphragm. The first and third story use Winco and Innotech windows that wrap around the corner. On the second story, a drift joint was used at the corner, similar to CFS 1.
  • CFS 4: This final sub-assembly is a finished, fire-rated glass curtain wall assembly whose glass rotates within its frame. It has steel mullions and 1 1/16 inches of thick fire-rated glass and was framed on site. 鈥淚t was designed for two-and-a-half percent drift, which is what we expect to see in the test itself,鈥 said Ryan.

FGIA Annual Conference Participants Tour Seismic Shake Table Test Site

鈥淚n most cases, we don鈥檛 expect the windows to be subjected to a lot of drift,鈥 said Ryan, with the exception of the corner window units on CFS 3.

Beneath the building sits the shake table itself. Actuators drive the shake table platform in all directions. The table moves a maximum of 35 inches in the East-West direction, 15 inches in the North-South direction, and 5 inches up and down, according to Site Manager, Koorosh Loftizadeh. At a payload capacity of 1100 kips, about twice that of the timber building, the peak acceleration capacity is 1.6g, 1.2g, and 0.6g (鈥済鈥 referring to acceleration of gravity at Earth鈥檚 surface) in East-West, North-South and vertical directions, respectively. To be ready for testing, more than 700 sensors and approximately 60 video cameras need to be installed in the building.

During the Seismic and Wind-Induced Inter-Story Drift Review Task Group (AAMA 501.4 and 501.7) meeting held at the FGIA Annual Conference, Ryan provided an update on how testing will go. 鈥淲e will impose a range of intensities over a four-week period, starting with a low level of shaking and building up to larger earthquakes through design level shaking to maximum considered earthquake (MCE),鈥 she said. 鈥淲e plan to scale up from low level drifts up to 2 percent inter-story drift. Some of the input motions will have peak acceleration over 1g.鈥

FGIA Annual Conference Participants Tour Seismic Shake Table Test Site

William Roser, research student, shared some predictions for the test. 鈥淲e are modeling the structure to predict the responses during the test,鈥 Roser said. 鈥淎s we change the design of the building and the mass of the building itself, that has caused our expected drift to be different from original drifts. The drifts are not quite as high as originally predicted.鈥 Ryan added that the team will adjust accordingly if the model is too conservative. The group hopes to begin testing at the end of March. Multi-camera streaming of the construction site can be seen and will be available to view this spring when the four-week test begins.

鈥淚t will be great to see it in action on that live feed,鈥 said Tanya Dolby, Chair of the FGIA task group.

For more information about FGIA and its activities, visit .

600450 FGIA Annual Conference Participants Tour Seismic Shake Table Test Site 黑料专区

Others also read

Italian Schiatti technology on the road for the North African flat glass market.
Experts on both the economy and daylighting will present during the Fenestration and Glazing Industry Alliance (FGIA) Virtual Summer Summit, taking place online June 23-24.
British Glass has expressed concern over the UK Government鈥檚 latest industrial decarbonisation support announcement, warning that the glass sector risks being left behind during the transition to Net Zero.
黑料专区 industry professionals are being urged to secure their place now for the milestone 20th Furnace Solutions Conference taking place in St Helens, UK, on 3鈥4 June 2026.
The Asia Fa莽ade & Glass Conference 2026 is now inviting industry experts, innovators and thought leaders to submit papers exploring the future of sustainable fa莽ades, smart glass technologies and advanced manufacturing solutions.
On the occasion of GIMAV鈥檚 business mission to Morocco, held in Casablanca from 4 to 7 May 2026, the international journey leading up to VITRUM 2027 was presented.

Add new comment