ºÚÁÏ×¨Çø

Frequently Asked Questions – Sparklike Handheld Nova

Date: 13 April 2026
Source:
Frequently Asked Questions – Sparklike Handheld Nova
Photo source
Sparklike

Date: 13 April 2026

A practical FAQ guide to the Sparklike Handheld NOVAâ„¢, answering key questions on fast, reliable, and non-destructive gas measurement for insulating glass production.

ºÚÁÏ×¨Çø

Ensuring the correct gas fill rate in double glazed insulating glass units is essential for consistent product quality and compliance with industry standards. Yet, many questions arise when selecting and using measurement equipment in daily production.

The is developed to provide a fast, reliable, and non-destructive way to verify argon concentration directly from sealed units. Built on proven spark emission spectroscopy technology, it delivers results in approximately two seconds while supporting efficient workflows in factory environments.

As the next generation of Sparklike handheld devices, NOVA introduces improved usability, enhanced data handling, and optional traceability features, all designed to support modern insulating glass production processes.

In the following FAQ, we answer the most common questions about Handheld NOVAâ„¢, including its technology, applications, compatibility with different glass structures, and how it integrates into quality control routines.

What is new in Sparklike Handheld NOVAâ„¢ compared to Handheld 3.0?

Answer:
Sparklike Handheld NOVAâ„¢ is an updated generation of the Handheld device. While the measurement technology and measurement time remain the same, NOVA introduces an updated design and improved functionalities that support more efficient daily production use, including enhanced usability and expanded data handling options.

Read

Sparklike Handheld Nova

Does Handheld NOVAâ„¢ use the same measurement technology as Handheld 3.0?

Answer:
Yes. Handheld NOVAâ„¢ uses the same spark emission spectroscopy technology as previous Handheld generations. This ensures reliable, non-destructive argon measurement in sealed insulating glass units, with measurement results available in approximately 2 seconds.

.

Where is Sparklike Handheld NOVAâ„¢ typically used?

Answer:
Handheld NOVAâ„¢ is primarily designed for use in factories, supporting quality control at different stages of the insulating glass production process.

Sparklike does not recommend using the Handheld device in direct sunlight, as strong ambient light can interfere with measurement accuracy. However, it has been successfully used in some cases for measuring installed windows. As a rule of thumb, accurate results depend on knowing the glass structure being measured.

What types of insulating glass units can Handheld NOVAâ„¢ measure?

Answer:
Handheld NOVA™ is designed for double glazed insulating glass units filled with argon. Measurement range is between 50 – 100 %.

The device measures gas concentration non-destructively through the glass.

Handheld NOVA

Can Handheld NOVAâ„¢ be used on coated or laminated glass?

Answer:
Sparklike Handheld NOVAâ„¢ can measure certain coated and laminated double glazed insulating glass units, but there are limitations depending on the glass structure.

Low-E coatings:
Yes. Handheld NOVAâ„¢ can measure double glazed insulating glass units with one Low-E coating, provided the other pane is clear glass. The measurement must always be taken through the clear side, as Low-E coatings reflect the light emission used in spark emission spectroscopy.

Laminated glass:
Handheld NOVAâ„¢ can measure through thin laminated glass under specific conditions:

  • Typically one or two interlayers of 0.38 mm each (e.g. 3+3 mm or 4+4 mm glass)
  • Higher gas fill rates improve spark penetration (Measurement range: 50 – 100 %).
  • Measurement should be taken close to the spacer for best accuracy
  • The spark must be visible during measurement

Laminated units with multiple interlayers or excessive thickness may not produce reliable results.

For insulating glass units with multiple coatings, complex laminations, or triple glazing, Sparklike recommends using a Sparklike Laser device, which measures through coatings and laminations using laser (TDLAS) technology.

What gases can Sparklike Handheld NOVAâ„¢ measure?

Answer:
Handheld NOVAâ„¢ measures argon as standard. Krypton measurement is available as an optional configuration.

Please note that the gas type cannot be changed later, as the measurement configuration is defined during production. Customers should confirm their preferred gas type when ordering the device.

How fast is the measurement process?

Answer:
A single measurement takes approximately 2 seconds. The device provides immediate results, supporting efficient quality control without slowing down production.

How is Handheld NOVAâ„¢ used in practice?

Answer:
The user places the device against the glass surface, initiates the measurement, and receives the gas concentration result directly on the device.

Can Handheld NOVAâ„¢ store or transfer measurement results?

Answer:
Yes. Handheld NOVA™ stores measurement results and supports wireless data transfer to Sparklike’s web-based software. Results can also be linked to individual insulating glass units using optional QR-code-based traceability.

Note: Does not operate as a network-connected IP device.

Handheld NOVA

Is Handheld NOVAâ„¢ suitable for factory and on-site use?

Answer:
Yes. Handheld NOVAâ„¢ is a handheld, battery-operated device designed primarily for production environments, but it can also be used for on-site inspections.

Please note that direct sunlight can interfere with measurement accuracy. Accurate on-site results depend on knowing the glass structure being measured.

What level of accuracy can I expect?

Answer:
Handheld NOVAâ„¢ uses spark emission spectroscopy compliant with ASTM E2649-20. The technology enables repeatable and reliable determination of argon concentration in sealed insulating glass units.

Independent testing performed by ift Rosenheim for Sparklike Handheld 3.0, which uses the same spark emission spectroscopy technology, demonstrated an average deviation of ±1.0% compared to gas chromatography. .

Is Handheld NOVAâ„¢ suitable for existing Handheld 3.0 users?

Answer:
Yes. Handheld NOVAâ„¢ is designed as the next generation of Sparklike Handheld. The updated design and improved functionalities make it suitable for users who want enhanced usability and workflow support in daily production and quality control.

Can Handheld NOVAâ„¢ be used in the same applications as Handheld 3.0?

Answer:
Yes. Handheld NOVAâ„¢ is intended for the same core applications as previous Handheld devices, including production quality control, routine inspections, and on-site measurement of double glazed insulating glass units.

Does Handheld NOVAâ„¢ support unit-level traceability?

Answer:
Yes. Handheld NOVAâ„¢ supports optional unit-level traceability by linking measurement results to individual insulating glass units via QR codes and supported barcode formats.

Handheld NOVA

Is Handheld NOVAâ„¢ battery-operated?

Answer:
Yes. Handheld NOVAâ„¢ is a handheld, battery-operated device designed for use in production environments and on-site inspections without the need for external power.

How long does the Handheld NOVAâ„¢ battery last?

Answer:

Handheld NOVAâ„¢ battery last approximately 16 hours.

Will Handheld 3.0 and previous models still be supported?

Answer:
Yes. Sparklike continues to support existing Handheld devices according to its standard service and support policies. Customers using Handheld 3.0 can continue normal operation and maintenance like Sparklike Handheld 2.0.

Customers will be informed if their Sparklike device maintenance or calibration ends.

Handheld 3.0

Do I need new training to use Handheld NOVAâ„¢?

Answer:
Handheld NOVAâ„¢ is designed for intuitive use. Both new and existing Handheld users can start using NOVA quickly.

Can Handheld NOVAâ„¢ measure krypton?

Answer:
Yes. Krypton measurement is available as an optional feature, depending on the device configuration.

600450 Frequently Asked Questions – Sparklike Handheld Nova ºÚÁÏרÇø

Others also read

The initiative offered customers a firsthand look at Fenzi’s production processes, innovation, and expertise in solutions for the glass processing industry.
In this episode, Glaston CEO Miika Äppelqvist sits down with Mr. Li Chang, Founder of Fuxuan Doors & Windows, to discuss the development of ultra-thin triple insulating glass technology in China.
China Glass 2026 highlighted the growing industry emphasis on insulating glass quality control, gas fill verification, and compliance with evolving IGU standards.
Impressive success story in modern insulating glass production
Insights from a 2022 Independent Study on Gas Content Stability in Inflatable IGUs
Over two decades, Sparklike has evolved its non-destructive gas measurement technology to meet the needs of modern insulating glass production.

Add new comment